HPLC Columns and Cartridges
Filtered Search Results

Thermo Scientific™ Hypersil GOLD™ Phenyl HPLC Columns

Use for quick analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
Pore Size | 175 Å |
---|---|
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 220 m²/g |
USP Type | L11 |
Thermo Scientific™ GuardGOLD™ Capillary Columns
Protect your analytical column from damage and contamination from nonvolatile materials.
Thermo Scientific™ Hypersil™ Silica Normal Phase HPLC Column, 3 μm, 4.6 mm x 250 mm
Column Format: Analytical Column; Carbon Load: 0%; Pore Size: 120 Å; Column Phase: Normal Phase
Thermo Scientific™ SurePac™ Bio 550 SEC MDi™ HPLC Columns
Experience the future of Size-Exclusion Chromatography (SEC) with SurePac™ Bio 550 SEC MDi™ analytical columns and guards exclusively designed to deliver robust and reproducible performance at high resolution and throughput to accelerate your therapeutics analysis process.
Particle Size | 3 μm |
---|---|
Stationary Phase | Proprietary |
Temperature | 20°C to 60°C |
Phase | Size Exclusion |
Packing Material | Monodisperse Silica Resin |
pH | 2 to 8 |
Quantity | 1 Ea. |
Technique | SEC |
Thermo Scientific™ BetaSil™ C8 HPLC Columns, 5μm Particle Size
High surface area with high bonded phase coverage
Pore Size | 100 Å |
---|---|
Stationary Phase | C8 |
Phase | Reversed Phase |
For Use With | LC/MS Separation |
Endcapped | Yes |
Column Type | Reversed Phase |
Column Chemistry | Octyl |
Surface Area | 310 m²/g |
Particle Size | 5 μm |
Carbon Load | 12% |
Packing Material | Silica |
pH | 2 to 9 |
Particle Shape | Spherical |
Film Thickness | 5 μm |
USP Type | L7 |
Thermo Scientific™ BetaSil™ C6 HPLC Columns, 5μm Particle Size
High surface area with high bonded phase coverage
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 11% |
Stationary Phase | C6 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
USP Type | L15 |
Column Format | Analytical Column |
Thermo Scientific™ BetaBasic™ 8 Javelin Guard Columns
A good first choice for compounds typically considered difficult to analyze
Pore Size | 150Å |
---|---|
Particle Size | 5 μm |
Stationary Phase | BetaBasic 8 |
Type | HPLC Column |
Carbon Load | 7% |
Endcapped | No |
For Use With (Equipment) | Analytical HPLC Column |
pH | 2 to 8 |
Surface Area | 200 m2/g |
USP Type | L7 |
Thermo Scientific™ BetaBasic™ 18 Guard Cartridges
Available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 150Å |
---|---|
Carbon Load | 13% |
Length (Metric) | 10 mm |
Endcapped | Yes |
For Use With (Equipment) | Uniguard Direct-connection and Stand Alone Holder |
pH | 2 to 12 |
Surface Area | 200 m2/g |
USP Type | L1 |
Thermo Scientific™ BetaBasic™ 8 Guard Cartridges, 5μm Particle Size
Thermo Scientific™ BetaBasic™ 8 Guard Cartridges are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 150Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 7% |
Length (Metric) | 10 mm |
Endcapped | Yes |
For Use With (Equipment) | Uniguard Direct-connection and Stand Alone Holder |
pH | 2 to 9 |
Surface Area | 200 m2/g |
USP Type | L7 |
Thermo Scientific™ BetaBasic™ 4 HPLC Columns, 5μm Particle Size

A good first choice for compounds with poor peak symmetry on other columns
Pore Size | 150 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 6% |
Stationary Phase | C4 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
USP Type | L26 |
Thermo Scientific™ BetaBasic™ CN Particle Size Guard Cartridges, 5μm Particle Size
Thermo Scientific™ BetaBasic™ CN Particle Size Guard Cartridges are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 150Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 5% |
Length (Metric) | 10 mm |
Endcapped | Yes |
For Use With (Equipment) | Uniguard Direct-connection and Stand Alone Holder |
pH | 2 to 9 |
Surface Area | 200 m2/g |
USP Type | L10 |
Thermo Scientific™ BetaBasic™ Phenyl Columns, 5μm Particle Size

BetaBasic columns are highly efficient and reproducible for small molecules, peptides and protein digests
Pore Size | 150 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 7% |
Stationary Phase | Phenyl (Ph) |
Phase | Reversed Phase |
For Use With | LC/MS Separation |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
Surface Area | 200 m²/g |
Particle Shape | Spherical |
Film Thickness | 5 μm |
USP Type | L11 |
Thermo Scientific™ BioBasic™ 4 HPLC Columns
Use this 300Å wide pore silica for analysis of larger hydrophobic proteins and peptides that bind too tightly on C8 or C18 columns.
Pore Size | 300 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 4% |
Stationary Phase | C4 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 100 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L26 |
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 11% |
Stationary Phase | Phenyl/Hexyl |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Product Line | Beta |
USP Type | L11 |
Thermo Scientific™ BioBasic™ AX HPLC Columns
Use Thermo Scientific™ BioBasic™ AX LC Columns for the separation of proteins, peptides, other anionic species and highly polar molecules.
Pore Size | 300 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 3% |
Stationary Phase | Polyethyleneimine |
Temperature | 60°C |
pH | 2 to 8 |
Surface Area | 100 m²/g |
Max. Pressure | 5800 psi (400 bar) |